Technical Parameter
| | | |
Operating Voltage | Automatic reclosing | AC175-240V AC100-240V | Access AC voltage range: AC90-264V 50-60Hz |
Device Interface | Network transmission | LC/SC fiber port | 2*100/1000M SFP fiber ports (Optional LC / SC interface) |
Gigabit RJ45 port | 8*10/100/1000Base-X RJ45 ports |
Console port | 1set Ethernet switch console configuration interface |
| POE power supply | Port 1-7 support IEEE802.3af/at POE output |
DC48V power interface | 1 set single output 250W / 48V DC power supply |
DC12V power interface | 1 set 3-port output 90W / 12V DC power supply, 12V / 2A |
AC24V power interface | 1 set single output 60W / 24V AC power supply |
AC220V power interface | 5 hole AC power socket |
Data control | RS485 interface | 1 set RS485 communication interface |
RS232 interface | 1 set RS232 communication interface |
Switch output | 1 set switch output (Connect the alarm circuit, alarm indicator, etc.) |
Switch input | 2 set switch input (Box door switch, water leak detection) |
Protective Function | Lightning protection | Network lightning protection | 6-port gigabit network lightning protection |
40KA anti-surge protection (SPD) | 40KA AC surge protector |
Automatic reclosing | Short circuit protection | In case of short-circuit fault, the power-off action time ≤0.1S |
Electric leakage protection | Electric Leakage current> 30mA, power-off action time≤0.1S |
Over current / overload protection | Power-off protection when the current is greater than 1.15 times the rated current and greater than 30S or the instantaneous current is greater than 3 times the rated current |
Over voltage protection | Power-off protection when the supply voltage is higher than the rated upper limit working voltage + 5V |
Under voltage protection | Power-off protection when the supply voltage is higher than the rated lower limit working voltage -5V |
Detection and protection before closing | Failure to restart before closing |
Operation and Maintenance | Data control | Main control board parameters | Flash:4GByte DDR: 512MByte CPU: ARM 600MHz |
Unauthorized unpacking monitoring alarm and video | Illegal unpacking alarm, video recording, and upload. |
Power failure alarm | DC12V power failure alarm AC220V mains power failure alarm |
Fan status monitoring alarm | Fan failure alarm Fan speed control |
Temperature detection alarm | Alarm temperature setting, Above the upper-temp limit, start the fan to dissipate heat; Less than the lower temp limit, start the chassis heating (The heating module needs to be purchased separately) |
Water leak detection alarm | Chassis flooding alarm |
Power monitoring alarm | Real-time alarm for mains over-voltage, under-voltage, lightning strike,short circuit fault |
Lightning protection frequency monitoring | Count lightning strike times to protect equipment installation and maintenance in advance |
Power consumption statistics | Real-time display of chassis voltage, current, power |
Output voltage / current control and monitoring alarm | DC12V output control and alarm AC24V output control and alarm AC220V output control and alarm PoE power output control and alarm |
System information display screen | Company LOGO Local management IP address Query / display the local I / O port status information Query / display the information of local voltage and current consumption. |
SMS alarm | The platform sends an alarm message SMS to the mobile phone of the operation and maintenance personnel |
Network transmission | PoE output network management | Delay start of power supply Scheduling of PoE operation and time PoE port real-time power viewing, PoE port power priority configuration PoE output power allocation, off& af &at |
PoE switch network management configuration | DHCP Serve, IGMP multicast Port mirroring, Port rate setting Network VLAN division Link aggregation, QoS configuration Network storm suppression MAC + VLAN + IP + port binding IPV4 / IPV6 dual stack protocol 802.1X access control, 802.3X flow control ERPS and spanning tree ring network networking, etc. |
Internet self-healing (Network watchdog) | Network traffic monitoring, offline recovery, downtime recovery, and storm recovery. |
Network monitoring alarm | Network port dropped alarm Optical port dropped alarm |
Device connection topology and status monitoring alarm | intelligent box connection topology Rename device name Custom topology design |
Expansion Module | Data control | 4G wireless transmission | 4G wireless communication function expansion and control |
Intelligent box heating | The automatic heating system is suitable for long-term low-temperature environment operation |
GPS positioning | Positioning accuracy ± 0.5 meters |
Local information storage | Specify or select local system information backup, local storage, provide accurate operation and maintenance information records |
Chassis repair lights | LDE Light when the box door is opened, providing lighting for smart box installation and maintenance. |
Chassis Protection | Case shell | Chassis protection level | IP55 |
Fan | 3200RPM |
Power supply air switch | AC220V/16A air switch |
Dimension | H*W*T:540x440x240mm |
Chassis material | 1.8mm galvanized steel sheet |
Insect net | The ventilation holes are covered with insect nets to ensure the interior of the box is clear |
Product Overview
It is an intelligent transmission and power control system with high integration, high functionality, and simple use. It has a modular structure and provides multiple sets of power output and remote monitoring control. The transmission module can be selected according to the application requirements to realize the optical transmission of various topologies.
Features
● Large multifunctional intelligent box.
● The box body adopts high strength cold rolled steel plate as a whole galvanized spray
● Equipped with one intelligent control 12V fan cooling system. When the temperature is higher than the set value, the fan starts to dissipate heat.
● With two intelligent dust removal fans.
● It has the function of monitoring tilt and collision. When the box tilts or is hit, the background will raise an alarm.
● Support real-time monitoring of mains input voltage, power failure alarm, reclosing trip report, remote power failure, power-on, restart function.
● It can determine whether the alarm is caused by the mains power failure or the equipment itself.
● Built-in backup battery, when the mains power failure support to continue to work, and report to the platform.
● Support box door switch status monitoring, abnormal open alarm.
● Electromagnetic lock device, remote consent to open the door.
● Support lightning arrester status monitoring, abnormal alarm.
● Monitor whether the box is waterlogged (optional).
● Support magnetic lock remote authorization opening and bluetooth unlocking (optional).
● Support box power consumption statistics (optional).
● Box supports the function of opening with the door.
● Guide rail installation structure, convenient installation of power switch and power surge protection module.
● Built-in optical fiber welding box
● Built-in two or three plug 220V power socket, can remotely control the output switch state.
● Built-in 220V40KA lightning protection unit.
● AC220V, AC24V and DC12V provide status indicators.
● Power output can remotely control the switching state.
● Power output built-in lightning protection unit.
Product picture

Packaging & Shipping
● All of our package are international standard package